Every engineering office uses their own set of symbols; however, the symbols below are fairly common across many offices. Refer to the symbol sheet for special symbols used in a particular set.

Bluebeam Tools and Templates Tool sets, hatches, line types, stamps, and templates for Bluebeam Revu. Best Architecture Books Our list of the top reference books for architects - these are the ones we have on our shelf.

Archtoolbox Guide to Fee Development A guide and toolbox of excel templates to help you develop a fee for architectural services. Stay ahead of the curve with news and tips about architecture practice, leadership, project management, and career growth.

Electrical Plan Symbols - Power. Duplex Outlet. Weatherproof Duplex Outlet. Duplex Outlet on Emergency Branch. Double Duplex Outlet aka Quad Outlet. Switch with Built-In Dimmer. Power Panel. Lighting Panel. Through-Wall Sleeve.

Junction Box. Recessed Floor Box. Help make Archtoolbox better for everyone. If you found an error or out of date information in this article even if it is just a minor typoplease let us know.

Related Archtoolbox Articles.Switchesoutlets, plugs, receptacles, connectors, GFCI etc are designed and rated with different rating having different electrical characteristics. The rating of switches depends on multiple factors i. There are two main rating for a switch:. All the switches, breakers, plugs, outlets, connectors and wires etc having two amperage rating. Safe maximum: switches, plugs, breakers, connectors, wires etc have a safe max amps.

The maximum current rating depends on the circuit voltage and should never exceed the exact current rating. If it exceeds, it will melt and weld the switch contacts and the switch will be useless. If there is no breaker, it may lead to damage the connected device even cause a dangerous fire.

In simple words, A 15A switch should not be used for 20A load current. Mostly, 30A 10 gauge circuits are used for V AC supply according the load wattage i. Most residential devices are 15A, but on occasion a 20A device may be appropriate. Related Switch Wiring Tutorials:. Example: What is the safe maximum current in amperes of a 15A switch? It means, a 15A switch can be used safely for a 12A load current.

Although, the 15A swicth can be used for exact 15A switch for non-continuous non-simultaneous load. While in case of continuous load, a 15A switch should be used for maximum of 12A load circuit. Voltage rating of a switch shows the maximum allowable voltage of the circuit where the switch has to be used for different loads.

A switch can be rated for AC voltageDC voltage or both having different values and ampacity. Read the user manual or nameplate data on the switch before installation. The supply voltage should never exceed the voltage rating of switch.

Electrical & Electronic Symbols

In other words, If we connect an V switch on V, the applied voltage may jump over the open contacts and overheat due to overvoltage of the circuit and connect the load to the supply voltage. It will lead to spark as well which may cause fire.

The breaker will open the circuit and stop the operation if current exceed the limit due to excessive voltage as compared to the rated voltage.By using our site, you acknowledge that you have read and understand our Cookie PolicyPrivacy Policyand our Terms of Service.

15a socket outlet symbol

It only takes a minute to sign up. OK, the one answer I got was way off target, and another commenter couldn't figure out what I was asking, so I'm restating the question Are 15A 3-prong grounded outlets actually rated to 20A, allowing them to be used on 20A circuits? And if so, why, when the outlet can never be asked to supply more than 15A by anything that would be plugged into it?

This question had a comment that 15A outlets were actually rated to 20A. However, by design, there is nothing that will plug into a 15A outlet that will draw more than 15A. An appliance that draws more than 15 amps would have a "T-blade" plug that wouldn't go into a standard 15A outlet. In addition, outlets are always wired in parallel, meaning that a 15A outlet would never have to transmit the amperage draw of a "downstream" outlet; you never "daisy-chain" outlets by connecting hot to neutral, for a number of reasons.

A 15A outlet is rated for 15A, with a 20A pass through. That is to say that the 20A circuit is in continuance throughout the circuit, however the receptacle itself the contacts are rated for 15A continuosly.

The total circuit draw multiple appliances - same circuit can be 20A before the breaker trips. A 20A breaker used with 12awg wire can feed multiple 15A outlets, one example is the kitchen. The reasoning is so that today's demanding appliances, which draw more current, can be used with a 20A breaker without the worry of nuisance tripping. If more than a total of 20A were to be drawn from the circuit, the breaker will trip. If it were to short, it will trip the 20A breaker just as it would a 15A breaker.

A 15A receptacle can take 20A for a short time with no problem. The receptacle is overrated, otherwise it would blow up upon a short.

A short circuit in actuality can be hundreds of amps in a very short duration. The breaker and receptacle are rated as "Time overcurrent" meaning it can take a lot of current for extremely short durations, and will trip on lesser currents that occur for a longer time. An example one can relate to refer to chart : Joe plugs in two electric heaters in his family room.

Everything works fine until seconds later the breaker trips! Joe overloaded his 20A circuit, by drawing 40A!According to NEC, an outlet is the point s in an electrical wiring system where current can be taken and utilize by electrical appliances and equipment by plugging them in it. An outlet receptacle where one or more receptacle are installed or a supply contact device installed at the outlet to connect an electrical load through plugs and switches.

Ordinary outlet or standard outlet has screws terminals on both sides. The brass screws should be connected to the line hot, live or phase wire while the silver screws should be connected to the Neutral wire. In other words, the hot wire from main breaker should be connected to the narrow blade terminal where the Neutral wire should be connected to the wide blade terminal.

Socket Outlets

The ground wire is connected to the ground terminal mostly green color screw. Keep in mind that the brass screws for hot terminals are electrically bounded to each other by a break way fin tab hence, connecting one brass screw to hot wire will feed the power to the second brass screw as well. In some case, you may remove the breakaway fin tab between the two brass screws for hot wire and split the outlet for other specific application we will show in following wiring diagrams.

In today wiring tutorials, we will be showing that how to wire and install an electrical outlet in different ways. In this simple wiring diagram, multiple outlets have been connected in parallel. Each outlet is independent of each others as they are wired to separate cables. The following wiring diagrams show that multiple outlets are wired to a single pole SPST switch, one-way or two way in US switch. In this wiring, a switch is added to to an existing outlet by removing the hot wire from outlet brass terminal and connected to the first terminal of switch.

The second terminal of switch then connected back to the brass terminal of outlet. In this wiring, a light switch has been added to the existing outlet. The hot terminal of outlet is connected to the first terminal of switch and the second terminal of switch is connected to the lighting point.

Finally, the neutral wire from outlet is connected to the light bulb. In this wiring, the outlet operation has been split into two parts i. To do this, simply remove the breakaway fin tab between the brass terminals hot as shown in fig. Connected the switch output hot to the upper brass terminal and the lower hot terminal should be connected to the switch input hot wire.

In simple words, a common hot wire should be connected to the first terminal of switch and lower hot terminal of outlet. The second terminal of switch as hot should be connected to the upper hot terminal of outlet.

15a socket outlet symbol

Finally, connect the neutral and ground wire accordingly as shown in fig below. In this wiring, the first and 3rd outlet hot terminals are connected to the Line 2 Blue and the second and last outlets hot terminals are connected to the Line 1 Red.

The neutral is connected from the main breaker to all outlets neutral terminal. Ground wire is connected to the outlets as well as shown in the fig. This way, all the dual outlets are connected to the single line of V and can supply V to the appliances. In this special wiring, a dual outlet is connected to both V and V where the upper portion provides V and the lower outlet provides V supply voltage.

The special receptacle outlet I, I are used in these kind of wiring.By Meg Escott. The placement of the outlets for all the electrical items in your home can have a significant impact on the design of your home. If you'd like a free pdf of all the blueprint and floor plan symbols go ahead and sign up below. Start by downloading your. I've included the symbols along with a bit of explanation and a checklist. Here goes Most of the electrical symbols used on blueprints have become standard. Some architects or designers may use slightly different symbols.

Always check with the key on your blueprints. If so, it should be explained somewhere in the key of the blueprint. All the outlets refer to wall outlets unless they are contained in square which means they're floor outlets. Tip for mobile browsers - these tables are best viewed with your phone in landscape position. Single outlet.

Electrical Plan Symbols - Power

Duplex outlet. Multiple outlet number denotes number of sockets. Duplex outlet with switch. Quad outlet.

GFCI outlet more explanation below. Special Power Outlet some examples below. Refrigerator outlet. Clothes washer outlet. Dish washer outlet. Clothes dryer outlet note v. Range outlet. Floor outlet. These outlets are required in places with water - so that's bathrooms and kitchens and maybe outside - especially near a swimming pool. It's so that if you drop your hairdryer in the bath you won't electrocute anyone! General outlets are where a wire is required to power a fixture where the fixture will be wired in rather than plugged in.

How to Add an Electric Outlet

The small horizontal line on the left of the circle indicates that the outlet is wall mounted. A circle without the horizontal line indicates that the outlet is mounted in the ceiling. Light outlet. Blanked unused outlet. Fan outlet. Junction box. Lamp holder. Lamp Holder with pull switch. Pull switch symbol.This list of outlet symbols will help you to identify these devices on the electrical blueprint or wiring diagram layout. When performing any electrical wiring for any of these outlets devices, you will be able to identify the type and location of the various devices from this list of outlet symbols.

The listing includes a description of the commonly used devices that are represented by these outlet symbols. In this listing of outlet symbols are a number of the most commonly installed receptacle outlets in the typical residential home. These outlets are found in various areas and rooms of the home where the most common type is a general purpose outlet, also known as a duplex receptacle.

The listing also contains other special purpose outlets as well. Electrical Wiring Diagram Symbols for Outlets Outlet The outlet symbol refers to an receptacle outlet which is volts. The most common outlet is referred to as a general purpose outlet and is found in most areas of the home.

In most installations the outlets is also a duplex outlet where there are two outlets in the same device and take up one space. The GFCI outlets is found in areas such as the kitchen and bathroom. Switched Outlet The switched outlet symbol generally refers to an outlet that is controlled by a switch.

Switched outlets are typically found in bedrooms. Waterproof Outlet The waterproof outlet symbol refers to an outlet that is located outdoors and is required to have a cover over the outlet that will make it waterproof. Quad Outlet The quad outlet symbol refers to two duplex receptacles that are mounted side by side in a two gang electrical box.

Floor Outlet The floor outlet symbol refers to an outlet that is flush mounted into a finished floor. A floor outlet may be a single outlet, duplex outlet or more. In some installations a floor outlet may be mounted in a divided electrical box where low voltage connections are provided for devices such as a TV or Data Port.

See How to Wire it Right! The Non-Contact Electrical Tester This is a testing tool that I have had in my personal electrical tool pouch for years, and is the first test tool I grab to help identify electrical wiring. Simply insert the end of the tester into an outlet, lamp socket, or hold the end of the tester against the wire you wish to test. Very handy and easy to use. This popular tester is also used by most inspectors to test for power and check the polarity of circuit wiring.

It detects probable improper wiring conditions in standard VAC outlets Provides 6 probable wiring conditions that are quick and easy to read for ultimate efficiency Lights indicate if wiring is correct and indicator light chart is included Tests standard 3-wire outlets UL Listed Light indicates if wiring is incorrect Very handy and easy to use.

Get a Quick Reply! Ask an Electrician Outlet Symbols. Questions about Wiring Diagrams and Outlet Symbols. The Wire Stripper and Wire Cutter My absolute favorite wire stripping tool that I have had in my personal electrical tool pouch for years, and this is the tool I use to safely strip electrical wires. This handy tool has multiple uses: The wire gauges are shown on the side of the tool so you know which slot to use for stripping insulation.

The end of the tool can be used to grip and bend wire which is handy for attaching wire onto the screw terminals of switches and outlets. The wire stripper will work on both solid and stranded wire. This tool is Very Handy and Easy to Use. Estimated Time: Depends on personal level experience, ability to produce drawings or draw scaled drawings or work with CAD Design Software.

Electrical Symbols must be used to identify the proposed circuit or electrical equipment or device. Residential Electrical Parts and Materials: Electrical parts and materials for home wiring projects should be approved for the specific project and compliant with local and national electrical codes. Electrical Codes and Inspections: Home Electrical Circuit Designs must be made in compliance with all Applicable Local and National Electrical Codes and Electrical Plans must be submitted to the appropriate building department or agency for approval as required for the specific project.

Outlet The outlet symbol refers to an receptacle outlet which is volts. Return to: Wiring Diagrams and Electrical Symbols. Residential Wiring Book.Free electrical installation pictures Temporary site flood lighting pics How to install electric DB Construction electricity supply photos Electrical engineering basics.

Post a Comment.

15a socket outlet symbol

Monday, April 18, House electrical symbols. If you are surprised at how short the list it, then please know that this list of electrical symbols has been used in this country for thirty or maybe forty years.

As I said, I am breaking up the original article, Home electrical wiring, symbols and checkinginto a number of small posts for the benefit of beginners so they can easily find what they are looking for. Lighting symbol 1: 4 ft, 1 x 36 watt fluorescent light fitting, wall mounted type. Lighting symbol 2: 2 ft, 1 x 18 watt fluorescent fitting, ceiling mounted type. Lighting symbol 3: Globe-type light fitting complete with 1 x 60 watt incandescent bulb, wall-mounted type. Lighting symbol 4: Globe-type light fitting complete with 1 x 60 watt incandescent bulb, ceiling-mounted type.

Fan symbol: inch ceiling fan. Socket symbol: 13A 3-pin switched socket outlet, wall mounted. There you have it. The symbols for a simple house electrical installation. I have broken up the symbols from the original drawing for the benefit of the internet search engines, so they can find this post easily. That also means internet users can find them easily.

Outlet Symbols

Diagram House electrical symbols. Click in the image to see the full size. This is the actual quantity of the materials in the original electrical layout, which you can see at this post, Simple house electrical schematic Coming soon That is all I wish to say in this post. I will see you again in the next small post. Posted by Wan at AM. Labels: House Electrical Symbols. No comments:. Newer Post Older Post Home. Kontera Tag. Analytic Codes. Auto Ad Code.